1240 Resistenza di calibrazione

Design a bassa capacità e induttanza, ideale per correnti dirette e frequenze tecniche, elevata stabilità < ± 0.01 % per anni.

  • Features

    • Range di misura 10 μΩ ... 100 kΩ
    • Bassa capacità e induttanza
    • Ideale per correnti dirette e frequenze tecniche
    • Elevata stabilità < ± 0.01 % per anni
  • Product data

    Model 1240
    Resistance value

    10 μΩ
    25 μΩ
    50 μΩ
    100 μΩ
    200 μΩ
    500 μΩ
    1 mΩ
    2 mΩ
    5 mΩ
    10 mΩ
    20 mΩ
    50 mΩ
    100 mΩ
    200 mΩ
    500 mΩ
    1 Ω
    2 Ω
    5 Ω
    10 Ω
    20 Ω
    50 Ω
    100 Ω
    200 Ω
    500 Ω
    1 kΩ
    2 kΩ
    5 kΩ
    10 kΩ
    20 kΩ
    50 kΩ
    100 kΩ

    Tolerance

    ± 0.02 %
    ± 0.03 %
    ± 0.05 %
    ± 0.1 %
    ± 1 %

    Temperature coefficient

    ≤ ± 10 ppm/K

    Storage stability < ± 0.01 % over years
    Power 2.5 W
    Range of operating temperature 0 ... +23 ... +40 °C
    Specific characteristics
    • Low capacitance and low inductance design
    • Suitable for direct current and technical frequencies
    • High stability < ± 0.01 % over years
  • Description

    The 0.02 class calibration resistors excel in their modern design and small mechanical dimensions. Their ruggedness also ensures a long life. Calibration resistors of the 1240 series are used wherever very constant operating standards are required. 

    Typical main areas of application therefore include:

    • When normal resistors prove to be too large scale
    • For test and calibration of resistance measurement devices
    • For tests on electrical temperature measuring equipment
    • For laboratory setup of a Wheatstone bridge
    • As shunt resistor for accurate current measurement
    • As part of standard equipment in research laboratories
    • For a large part of measurements in calibration laboratory.

    A test certificate according to ISO 9000 with detailed technical data is included in the scope of delivery of these high-quality calibration resistors.

    DKD/DAkkS Calibration Certificate

    The calibration laboratory D-K-15141-01-00 at burster praezisionsmesstechnik gmbh & co kg is supervised by DAkkS (Deutsche Akkreditierungsstelle GmbH) according to ISO 17025. 
    It can prove its status by a certificate and is authorized to issue calibration certificates with the DAkkS logo and with the DKD logo (Deutscher Kalibrierdienst). 
    These calibration certificates are internationally approved by multilateral contracts.

    Manufacturer Calibration Certificate

    Please refer to DKD/DAkkS Calibration Certificate but with reduced accuracy. The calibration resistors can also be delivered with a manufacturer calibration certificate. It confirms the traceability of the used secondary voltage and resistance standards to the national standards according to DIN ISO 9000ff and is guaranteed by our certified calibration laboratory (D-K-15141-01-00).

  • Data Sheet & Downloads

    Data sheet


Riferimenti

Richiedi prodotto

    Confronta prodotto

      COILTECH 2019

      Venite a trovarci!
      COILTECH 2019
      25-26  Settembre - Pordenone (PN)

      Scopri i nostri nuovi prodotti!

      Scopri la nostra nuova brochure Celle di carico per produzione, automazione, R&D e controllo qualità con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Scarica la nostra nuova brochure

      Scoprite la nuova brochure Press-fitting - the reliable way. Controllo di qualità al 100% per le operazioni di pressatura manuale con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Download our new brochure

      Scoprite la nostra nuova brochure Torque Sensor con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Download our new brochure

      © 2019 // burster Italia s.r.l.
      nach